Product No: LS8517CX
Common mode inductor balance tester is also called filter balance tester. It is suitable for all kinds of common mode inductors, filter common mode inductors Ls, DCR balance measurement. Its measuring accuracy is up to 0.1% and it can meet the measurement requirements of production line quality assurance, incoming inspection and component design and evaluation. Equipped with a more comprehensive communication and control interface, the connection of automation equipment is simple and convenient.
The following are product models and differences, please purchase on demand:
• LS7575BN: Maximum frequency 10KHz, 4.3 “LCD 2U standard case
• LS1085CX: Test frequency 50-200kHz, DCR test function, standard test box, balance fixture
• LS8517CX-4PA: 2 pairs of winding test with frequency 50-200kHz, can simultaneously test Ls, DCR, cycle ratio, balance function
• LS8517CX-6PA: 3 pairs of winding test with frequency 50-200kHz, can simultaneously test Ls, DCR, cycle ratio, balance function
Model |
LS7575BN |
LS1085CX |
LS8517CX |
|
Test frequency
|
100Hz,120Hz,1kHz,10kHz |
50Hz~200kHz, 42 typical frequency points |
50Hz ~ 200kHz, 37 typical frequency points |
|
Test parameter |
L, Q, R |
L、C、R、Q、|Z|、DCR |
L、R、Q、|Z|、θ(RAD),C,DCR |
|
Test level |
0.1Vrms, 0.3Vrms, 1Vrms |
10mV~1Vrms |
50mV-2.0V,Continuously adjustable |
|
Basic accuracy |
0.1%,Accuracy table shall prevail |
0.05%,Accuracy table shall prevail |
||
Display range
|
|Z| |
– |
0.1 mΩ~99.999MΩ |
0.1 mΩ~99.999MΩ |
L |
0.0001μH~999.99H |
0.0001μH~9999.9H |
0.0001μH~999.99H/ 0.0001μH~9999.9H |
|
R |
0.01 mΩ~99.999MΩ |
0.1 mΩ~99.999MΩ |
0.01 mΩ~99.999MΩ |
|
Q |
0.0001~9999 |
0.0001~99999 |
0.1~9999.9 |
|
θ(RAD) |
– |
-3.14159~3.14159 |
||
θ(DEG) |
– |
-179.99 o ~179.99o |
||
Δ% |
– |
-99.999%~99.999% |
||
DCR |
– |
0.1 mΩ~99.999MΩ |
0.01mΩ-99.9999MΩ |
|
Test speed
|
Fast speed: 30 times/second, medium speed: 6 times/second, slow speed: 1.5 times/second |
Fast speed: 50 times/second, medium speed: 20 times/second, slow speed: 6 times/second |
||
Source impedance |
30Ω、100Ω |
30Ω、50Ω、100Ω、10/100Ω |
||
Range mode |
Automatic and hold |
|||
Trigger mode
|
Internal, manual, external |
Internal, manual, automatic, external, bus |
||
Calibration function |
Open/short circuit, full frequency clear zero |
|||
Equivalent circuit |
Series and parallel |
|||
Comparator
|
BIN0~BIN3、NG、Pass、Fail |
PASS、HI、LOW(PASS/FAILLED) |
||
PASS、HI、LOW(PASS/FAILLED)、Buzzer |
|
|||
Ports |
RS232C、UsbHost、USB Device、Handler |
|||
Memorizer |
– |
Internal 50 groups, external U disk 500 groups of files |
||
Working temperature humidity |
0℃~40℃,Relative humidity≤75% |
|||
Working power |
100~120 V AC/198~242 V AC, 46~64 Hz,Power >50 VA |
|||
Volume(WxHxD) |
310mmx110mmx315mm |
|||
Net weight |
2.5Kg |
5.5Kg |