+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語

IEC 60245-1 Clause 5.6.3.1 | IEC 60245-2 Clause 3.5 Figure 3 Flexing Test Apparatus for Flexible Cables

Product No: WDT-B42

Leave a Message

=
  • Description
  • The WDT-B42 Flexing Test Apparatus for Flexible Cables is according to IEC 60245-1 Clause 5.6.3.1 (GB/T 5013.1 Clause 5.6.3.1), IEC 60245-2 Clause 3.1 Figure 1 (GB/T 5013.2 Clause 3.1 Figure 1), IEC 60227-1 Clause 5.6.3.1 (GB/T 5023.1 Clause 5.6.3.1), IEC 60227-2 Clause 3.1 Figure 1 (GB/T 5023.2 Clause 3.1 Figure 1). It is suitable for mechanical strength testing for Flexible Cables after a certain number of bendings under dynamic load.

    The WDT-B42T Three Pulley Flexing Test Apparatus for Flexible Cables is fully meet IEC 60245-2 Clause 3.5 Figure 3 (GB/T 5013.2 Clause 3.1 Figure 3). It is suitable for mechanical strength testing for Flexible Cables after a certain number of bendings under dynamic load.

    Test principle: A 5m long specimen is reciprocated within a 1m stroke through a pair of pulleys to achieve bending test of wires and cables.

    Specifications:

    LISUN Model WDT-B42 WDT-B42T
    Pulley structure Two pulley structure Three pulley structure
    Bending speed 0.33m/s 0.1m/s
    Combination weights 0.5,1.0,2.0,3.0,7.0kg 21,28,42N
    Pulley diameter(mm) 60,80,120,160,200 40,45,50
    Test specimen type Two-wire single-phase; three-wire three-phase; four-wire three-phase
    Test method No-load, single-phase (two-wire),
    three-phase (three-phase three-wire/three-phase four-wire)
    Shutdown mode A、Can indicate: O, R, S, T phase disconnection
    B、Can indicate: R/S, R/T, S/T, R/O, S/O, T/O short circuit
    C、Can indicate: O, R, S, T and pulley short circuit
    Control method PLC program control, touch screen operation
    Flexure stroke ≥1M
    Test current 0~40A
    Test voltage Two-wire single-phase AC: 0~250V (adjustable); three-phase AC: 0~450V (adjustable); 50/60Hz

    IEC 60245-2 Clause 3.1 And Figure 1 (WDT-B42)

    IEC 60245-2: 1998 Figure 3 (WDT B42T)

    IEC 60245-2: 1998 Clause 3.5 (WDT-B42T)

    Tags: