IS 16102(Part 2): 2017 Self-Ballasted LED Lamps for General Lighting Services Part 2 Performance Requirements

This standard IS 16102(Part 2): 2017 specifies the performance requirements, together with the test methods and conditions, required to show compliance of LED lamps with integral means for stable operation, intended for domestic and similar general lighting purposes, having:
a) a rated power from 1 W to 25 W;
b) a rated voltage above 50 V ac up to and including 250 V ac at 50 Hz;
c)alamp cap as listed in IS 16102(Part1):‘Self- ballasted LED lamps for general lighting services: Part 1 Safety requirements’

These performance requirements are additional to the safety requirements specified in IS 16102(Part 1).

The only feature provided by this standard, when applied for replacement purposes, is information on maximum lamp outlines.

The requirements of this standard relate to acceptance and type testing.

This standard IS 16102(Part 2): 2017 covers LED lamps that intentionally produce white light, based on inorganic LEDs. This standard does not cover self-ballasted LED-lamps that intentionally produce tinted or coloured light neither does it covers OLEDs.

The life time of LED lamps is in most cases much longer than the practical test times. Consequently,verification of manufacturer’s life time claims cannot be made in a sufficiently confident way, because projecting test data further in time is not standardized. For that reason the acceptance or rejection of a manufacturer’s life time claim, past an operational time as stated in 7.1, is out of the scope of this standard.

Instead of life time validation, this standard has opted for lumen maintenance codes at a defined finite test time. Therefore, the code number does not imply a prediction of achievable life time. The categories, represented by the code, are lumen-depreciation
character categories showing behaviour in agreement with manufacturer’s information, provided before the test is started character categories showing behaviour in agreement with manufacturer’s mnformation provided before the test is started

LISUN supplies the fully test solutions for the following IS 16102(Part 2): 2017 , please see the below excel table:

Clause 3.3-3.8 Lumen Maintenance LEDLM-84PL
Clause 7 Test Conditions
Clause 11 Lumen Maintenance
Clause 3.9 Photometric Code LMS-6000
Clause 7.2.3 Compliance Testing of Family Members LPCE-2
Clause 9.1 and 9.3 Luminous Flux
Clause 14 Tests
Clause 8.3 Harmonics LS2090
Clause 8.4 Emission of Radio Frequency Disturbances RFCI61000-6
Clause 3.16-3.26 LED Luminous Intensity LSG1890B
Clause 9.2 Luminous Intensity Distribution,
Clause 10 Colour Nomenclature, Variation and Rendering LMS-6000