This Standard UL 1598: 2012 is issued jointly by the Association of Standardization and Certification (ANCE), the Canadian Standards Association (CSA),and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSA, or UL at any time. Revisions to this standard will be made only after processing according to the standards development procedures of ANCE, CSA,and UL. CSA and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE will incorporate the same revisions into a new edition of the standard bearing the same date of issue as the CSA and UL pages.
LISUN supplies the fully test solutions for the following UL 1598: 2012, please see the below excel table:
UL 1598: 2012 Clause and Subject | LISUN Model |
Clause 3 Ballast Tester | WT5000 |
Clause 5.6 Corrosion protection | YWX/Q-010 |
Clause 13.4.2 Corrosion protection | |
Clause 6.7.1.5 HID Ballast Tester | WT2000-HID |
Clause 6.11.1 Creepage Distances | CK-1 |
Clause 6.12 Electrical insulation | WB2681A |
Clause 6.14 Grounding and bonding | WB2678A |
Clause 18.2 Grounding continuity | |
Clause 12.2.3.1 Plastic material flame | ZY-3 |
Clause 16.3 Five-inch Flame | |
Clause 16.27 Needle flame | |
Clause 19.24&19.31 Five-inch flame test apparatus | |
Clause 12.3.3.1 Temperature | GDJS-015B |
Clause 12.3.3.2 Thermal shock | HLST-500D |
Clause 16.28 Lamp containment barrier thermal shock | |
Clause 16.2.3 Impact | IK01-06 |
Clause 16.5.7 Impact conditioning | |
Clause 16.22 Tempered glass impact | |
Clause 16.2.5.2 Torque | CH338 |
Clause 16.33 Lampholder mounting torque | |
Clause 19.27 Lampholder mounting torque test apparatus | |
Clause 16.5.1-16.5.4 Wet Locations | JL-X |
Clause 19.17 Rain test apparatus | |
Clause 19.18 Sprinkler test apparatus | |
Clause 16.5.5 UV exposure conditioning | UV-263LS |
Clause 19.25 UV exposure test apparatus | |
Clause 16.5.6 Polymeric thermal conditioning | GW-500 |
Clause 16.5.8 Luminaire gasket assembly accelerated aging | |
Clause 16.5.9 Gasket accelerated aging(Method A) | |
Clause 16.5.10 Gasket accelerated aging (Method B) | |
Clause 16.6 Hot-wire ignition (HWI) | RSY-LT |
Clause 16.7 Glow-wire end product | ZRS-3H |
Clause 19.28 Glow-wire test apparatus | |
Clause 16.8 High-current arc ignition (HAI) | HCAI-2 |
Clause 16.16-16.17 Snap-in or tab-mounted parts pull test with/without conduit opening | LNSYJ-1 |
Clause 16.25 Horizontal burning flame | HVR-LS |
Clause 16.26 Vertical burning flame | |
Clause 19.29 Horizontal burning flame test apparatus | |
Clause 19.30 Vertical burning flame test apparatus | |
Clause 17.1&18.1 Dielectric voltage-withstand | LS9923 |
Clause 19.20 Dielectric voltage-withstand test apparatus | |
Clause 17.2 Bonding circuit impedance | LS90 |
Clasue 19.21 Impact test apparatus | ZBP-T |
Clasue 19.22 Articulate probe | SMT-PA100A |