  • DSCD-950P Benchtop Spectrophotometer is an an intelligent, convenient and high precise spectrophotometer. It adopts 7 inches touch screen, full-spectrum capability, and an Android operating system. Illumination modes include reflection D/8° and transmission D/0° (with UV inclusion/exclusion measurements). It offers accurate and stable color measurements, a large storage capacity, and robust expansion capabilities on the PC end, making it suitable for laboratory color analysis and communication.

    Introduction:
    Adopts reflectance D/8° and transmittance D/0° geometry to measure both opaque and transparent materials.

    Dual Optical PathsSpectrum Analysis Technology
    This technology can simultaneous access to both measurement and instrument internal environmental reference data to ensure instrument accuracy and long-term stability.

    Compatible with SCI/SCE measurement, Support SCI+SCE Measurement
    Instrument adopts D/8 geometry which is highly recommends by CIE (International Commission on Illumination) to meet color measurement of different industries.It supports both SCI (specula component included) and SCE (specular component excluded) mode for better detect of color change.Fast SCI+SCE measurement, test time only need less than 4s.

    Rotatable Touch Screen with Android Operate System
    Screen position and direction can be adjusted according to the instrument test methods.

    Android Operate System

    Open Transmittance Measurement Area, no limit on sample size

    • Different Kinds of Accessories for simple measurement
    It contains 15 kinds of standard and 12 kinds of optional accessories to measure different kinds of materials

    • Accessory Drawer to Protect and Store Accessories

    • Switchable Reflectance Apertures

    • Four Kinds of UV Test Modes for Fluorescence Material Measurement

    Instrument Structure Introduction

    DSCD-920

    Specification:

    Illumination/ Viewing System

    Reflection: d/8(Diffused illumination, 8 degree viewing)

    Simultaneous measurement of SCI/SCE (ISO7724/1, CIE No.15, ASTM E1164, ASTM-D1003-07, DIN5033 Teil7, JIS Z8722 Condition C standard)

    Transmittance d/0(Diffused illumination, 0 degree viewing )

    Sensor

    Silicon Photodiode Array

    Grating Method

    Concave Grating

    Sphere Diameter

    152mm

    Wavelength

    360-780nm

    Wavelength Pitch

    10nm

    Half Band Width

    5nm

    Reflectance Range

    Resolution

    0-200%

    0.01%

    Light Source

    Pulse Xenon Lamp and LED

    UV Measurement

    Include UV, 400nm, 420nm, 460nm

    Measurement Time

    SCI/SCE < 2s

    SCI+SCE < 4s

    Measurement Aperture

    Reflection:
    XLAV Φ25.4mm/Φ30mm
    LAVΦ15mm/Φ18mm
    MAVΦ8mm/Φ11mm
    SAVΦ3mm/Φ6mm
    (Users can customize the caliber, and the caliber switch will be automatically recognized)
    Transmission: Φ17mm/Φ25mm

    Transmittance Sample Size

    No limit on sample width and height, thickness ≤50mm

    Repeatability

    XLAV Spectrum Reflectance/Transmittance: standard deviation within 0.1%
    XLAV chromaticity value: standard deviation ΔE*ab within 0.015 (after instrument calibration, measure the white calibration plate 30 times at 10 second intervals)

    Inter-Instrument Agreement

    XLAV ΔE*ab 0.15 (BCRA Series II, Average measurement of 12 tiles, at 23℃)

    Illuminants

    A, C, D50, D55, D65, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12, CWF, U30, DLF, NBF, TL83, TL84

    Language

    English, Russian, Spanish, Portuguese, Japanese, Thai, Korean, German, French, Polish, Chinese (simple and traditional), Indonesian

    Display

    Spectral data, spectral graph, colorimetric data, color difference data, color difference graph, pass/fail judgment, simulated color, color evaluation, haze, liquid color, color deviation

    Viewing Angles

    2° and 10°

    Color Spaces

    L*a*b, L*C*h, Hunter Lab, Yxy, XYZ

    Other Indices

    WI(ASTM E313-00,ASTM E313-73,CIE/ISO, AATCC, Hunter, Taube Berger, Stensby)

    YI(ASTM D1925, ASTM E313-00, ASTM E313-73), Tint(ASTM E313-00), Metamerism index milm, stain fastness, color fastness, ISO brightness, R457, A density, T density, E density, M Density, APHA/Pt-Co/Hazen, Gardner, Saybolt, ASTM color, Haze, Total Transmittance, Opacity, Color Strength

    Color Difference

    ΔE*ab, ΔE*CH, ΔE*uv, ΔE*cmc, ΔE*94, ΔE*00, ΔE*ab(hunter),555 shade sort

    Storage Memory

    8 GB U Disk for data storage and transfer

    Screen Size

    7 Inches Touch Screen

    Power

    12V/3A

    Operate Temperature

    5-40℃(40-104F), relative humidity 80% (at 35℃) no condensation

    Storage Temperature

    -20-45℃(-4-113F), relative humidity 80% (at 35℃) no condensation

    Accessories

    Power adapter, data cable, transmission fixture, USB flash drive (including management software), black chamber, white board, green board, 0% calibration light shielding cover, 30 mm aperture plate, 18 mm aperture plate, 11 mm aperture plate, 6 mm aperture plate, support table, cuvette, damping handle

    Optional Accessories

    Heating Fixture for Transmittance, Vertical Support and Pneumatic ram for downward measurement, Reflectance fixture for small size sample, Reflectance Glass Cell Support, Corrosion-Resistant Protective Plate (non-removable), Sample Holder for Fiber, Film Fixture, Transmittance Fixture for Small Aperture, Trolley Case, European Standard Plug, American Standard Plug

    Interface

    USB, USB-B and RS-232

    Instrument Size

    465x240x260mm(L*W*H)

    Weight

    10.8KGS

    Other Function

    1. Camera to view measurement area;

    2. Support horizontal, vertical and downward measurement method (need optional accessories to support for downward measurement);

    3. Auto humidity and temperature compensation function.

    Applications:
    • Plastic Plate Color Measurement

    Plastic Plate Color Measurement

    • Powder Material Color Measurement

    Powder Material Color Measurement

    • Petroleum and Oil Color and Transmittance Measurement

    Petroleum and Oil test

    • Textile and Yarn Color Measurement

    Textile and Yarn Color Measurement

    • Master Batches and other Pellet Material Color Measurement

    Master Batches and other Pellet Material Color Measurement

    • Printing Ink and Packing Material Color Measurement

    Master Batches and other Pellet Material Color Measurement

    Tags:
  • DSCD-920 Benchtop Spectrophotometer (Reflectance and Transmittance)

    vedio
  • DSCD-920 Calibrate Certificate