LEDs and Luminaire Test Solutions

Compliance Testing for LED Luminaires Based on CISPR 025/E:2015 and IEC 62722-2-1:2023
This article focuses on the importance of compliance testing for LED luminaires, particularly in relation to electromagnetic compatibility (EMC) and performance requirements. CISPR 025/E:2015 outlines EMC limits for lighting products used in vehicles, ensuring minimal interference with onboard electronics. Meanwhile, IEC 62722-2-1:2023 specifies performance characteristics and testing procedures for LED luminaires used in general lighting applications, covering aspects such as luminous efficacy, thermal performance, and reliability. The article discusses key testing methods, required measurement equipment, and challenges faced in achieving regulatory compliance.

Safety and Photometric Evaluation of LED Modules and Luminaires According to CIE 121:1996, IEC 60598-2-10, and IEC 62031:2008
This article explores the safety and photometric evaluation of LED modules and luminaires. CIE 121:1996 provides guidelines for photometric measurements, ensuring accurate evaluation of luminous flux, intensity distribution, and color characteristics. IEC 60598-2-10 addresses safety requirements for portable luminaires, including mechanical strength and electrical insulation. Additionally, IEC 62031:2008 specifies safety requirements for LED modules, focusing on thermal management, electrical insulation, and mechanical durability. The article highlights best practices for conducting photometric and safety tests, ensuring compliance with international standards while optimizing LED luminaire performance.

Standard:

Part 1 CIE S 025/E:2015 Test Method for LED Lamps, LED Luminaires and LED Modules and its supplement
Part 2 IEC 62722-2-1:2023 Luminaire performance – Part 2-1: Particular requirements-LED luminaires
Part 3 CIE 121:1996 The Photometry And Goniophotometry Of Luminaires
Part 4 IEC 60598-2-10 Luminaires – Part 2-10: Particular requirements – Portable luminaires for children
Part 5 IEC 62031:2008 IEC 62031: 2008 LED modules for general lighting-Safety specifications

Part 1 CIE S 025/E:2015 Test Method for LED Lamps, LED Luminaires and LED Modules and its supplement

LISUN supplies the fully test solutions for the following CIE S 025/E:2015, please see the below excel table:

CIE S 025/E:2015 Clause and Subject LISUN Model
4.3.3.2 AC Power Supply LSP-500VARC
4.3.3.3 DC Power Supply DC3005
4.4.2 LED Modules TRS-1000
4.5.2.2 Sphere- Photometer LPCE-2(LMS-9000)
4.5.3 Goniophotometer(All Types) LSG-6000LSG-1890B and LSG-1950
4.5.3.2 Gonio-Spectroradiometer LSG -6000CCD and LSG-1890BCCD
4.5.3.3 Gonio-colorimeter CD-320PRO
5.1 Aging  SY2036
6.4 Luminous Efficacy LPCE-2(LMS-9000)
6.7 Luminance Measurements KS-10
7. Measurement of Colour Quantitles LMS-6000
8.1.2 & 8.13 Luminous Flux &Luminous intensity LSG-1890B
8.15 Electric Power LS2050

Part 2 IEC 62722-2-1:2023 Luminaire performance – Part 2-1: Particular requirements-LED luminaires

LISUN supplies the fully test solutions for the following IEC 62031:2008, please see the below excel table:

IEC 62722-2-1:2023 Clause and Subject LISUN MODEL
Clause 8.1 Luminous flux LPCE-2(LMS-9000)
Clause 8.3 Luminaire luminous efficacy
Clause 8.2 Luminous intensity distribution, peak intensity and beam angle LSG-6000
Clause 9 Chromaticity coordinates, correlated colour temperature (CCT) and colour rendering LMS-6000
Clause 10 LED luminaire life LEDLM-84PL

Part 3 CIE 121:1996 The Photometry And Goniophotometry Of Luminaires

LISUN supplies the fully test solutions for the following CIE 121:1996, please see the below excel table:

CIE 121:1996 Clause and Subject LISUN MODEL
Clause 2.2.1 Luminaire data per 1 000 lm (of lamp flux) LPCE-2(LMS-9000)
Clause 2.2.4-2.2.7 Light output ratio (of a luminaire)
Clause 6.3 Luminous flux measurements on luminaires
Clause 2.2.2 Luminous intensity distribution (of a luminaire) LSG-6000
Clause 2.4.1-2.4.3 Photometer
Clause 3 CO-ORDINATE SYSTEMS FOR THE PHOTOMETRY OF LUMINAIRES
Clause 6.1.3 Photometric measurements on luminaires
Clause 6.2 Luminous intensity distribution measurements
Clause 2.2.3 Ballast lumen factor HCS-109A
Clause 2.3.6 Reference ballast
Clasue 7.4 Ballast lumen factor
Clause 2.4.4 Illuminance meter LMS-6000 And PHOTO-200
Clause 6.6 Illuminance measurements
Clause 6.3 Luminous flux measurements on luminaires LMS-6000L And PHOTO-200L

Part 4 IEC 60598-2-10: 2003 Luminaires – Part 2-10: Particular requirements – Portable luminaires for children

LISUN supplies the fully test solutions for the following IEC 60598-2-10:2003, please see the below excel table:

IEC 60598-2-10: 2003 Clause and Subject LISUN MODEL
Clause 10.7 Creepage distances and clearances CK-1
Clause 10.12 Endurance tests and thermal tests GDJS-015B
Clause 10.13 Resistance to dust, solid objects and moisture SC-015
JL-X
Clause 10.14 Insulation resistance and electric strength WB2681A
Clause 10.15 Resistance to heat, fire and tracking ZRS-3H
ZY-3
TTC-1

Part 5 IEC 62031: 2008 LED modules for general lighting-Safety specifications

LISUN supplies the fully test solutions for the following IEC 62031:2008, please see the below excel table:

IEC 62031:2008 Clause and Subject LISUN Model
3.11 heat transfer temperature for LED module TRS-1000
3.12 heat output to luminaire
Annex D Information for luminaire design (Figure D.1)
3.13 ultraviolet hazard efficacy of luminours radiation LMS-6000UV
9. Provisons for protective earthing WB2678A
11.Insuation Resistance test WB2681A
12. Electric strength WB2671B
16. Creepage distance and clearances CK-1
18. Resistance to heat,fire ZRS-3H
18. Resistance to tracking TTC-1
19. Resistance to corrosion YWX/Q-010
22 Photobiological safety EN 62471-C