Compliance Testing for LED Luminaires Based on CISPR 025/E:2015 and IEC 62722-2-1:2023
This article focuses on the importance of compliance testing for LED luminaires, particularly in relation to electromagnetic compatibility (EMC) and performance requirements. CISPR 025/E:2015 outlines EMC limits for lighting products used in vehicles, ensuring minimal interference with onboard electronics. Meanwhile, IEC 62722-2-1:2023 specifies performance characteristics and testing procedures for LED luminaires used in general lighting applications, covering aspects such as luminous efficacy, thermal performance, and reliability. The article discusses key testing methods, required measurement equipment, and challenges faced in achieving regulatory compliance.
Safety and Photometric Evaluation of LED Modules and Luminaires According to CIE 121:1996, IEC 60598-2-10, and IEC 62031:2008
This article explores the safety and photometric evaluation of LED modules and luminaires. CIE 121:1996 provides guidelines for photometric measurements, ensuring accurate evaluation of luminous flux, intensity distribution, and color characteristics. IEC 60598-2-10 addresses safety requirements for portable luminaires, including mechanical strength and electrical insulation. Additionally, IEC 62031:2008 specifies safety requirements for LED modules, focusing on thermal management, electrical insulation, and mechanical durability. The article highlights best practices for conducting photometric and safety tests, ensuring compliance with international standards while optimizing LED luminaire performance.
Standard:
Part 1 | CIE S 025/E:2015 | Test Method for LED Lamps, LED Luminaires and LED Modules and its supplement |
Part 2 | IEC 62722-2-1:2023 | Luminaire performance – Part 2-1: Particular requirements-LED luminaires |
Part 3 | CIE 121:1996 | The Photometry And Goniophotometry Of Luminaires |
Part 4 | IEC 60598-2-10 | Luminaires – Part 2-10: Particular requirements – Portable luminaires for children |
Part 5 | IEC 62031:2008 | IEC 62031: 2008 LED modules for general lighting-Safety specifications |
Part 1 CIE S 025/E:2015 Test Method for LED Lamps, LED Luminaires and LED Modules and its supplement
LISUN supplies the fully test solutions for the following CIE S 025/E:2015, please see the below excel table:
CIE S 025/E:2015 Clause and Subject | LISUN Model |
4.3.3.2 AC Power Supply | LSP-500VARC |
4.3.3.3 DC Power Supply | DC3005 |
4.4.2 LED Modules | TRS-1000 |
4.5.2.2 Sphere- Photometer | LPCE-2(LMS-9000) |
4.5.3 Goniophotometer(All Types) | LSG-6000, LSG-1890B and LSG-1950 |
4.5.3.2 Gonio-Spectroradiometer | LSG -6000CCD and LSG-1890BCCD |
4.5.3.3 Gonio-colorimeter | CD-320PRO |
5.1 Aging | SY2036 |
6.4 Luminous Efficacy | LPCE-2(LMS-9000) |
6.7 Luminance Measurements | KS-10 |
7. Measurement of Colour Quantitles | LMS-6000 |
8.1.2 & 8.13 Luminous Flux &Luminous intensity | LSG-1890B |
8.15 Electric Power | LS2050 |
Part 2 IEC 62722-2-1:2023 Luminaire performance – Part 2-1: Particular requirements-LED luminaires
LISUN supplies the fully test solutions for the following IEC 62031:2008, please see the below excel table:
IEC 62722-2-1:2023 Clause and Subject | LISUN MODEL |
Clause 8.1 Luminous flux | LPCE-2(LMS-9000) |
Clause 8.3 Luminaire luminous efficacy | |
Clause 8.2 Luminous intensity distribution, peak intensity and beam angle | LSG-6000 |
Clause 9 Chromaticity coordinates, correlated colour temperature (CCT) and colour rendering | LMS-6000 |
Clause 10 LED luminaire life | LEDLM-84PL |
Part 3 CIE 121:1996 The Photometry And Goniophotometry Of Luminaires
LISUN supplies the fully test solutions for the following CIE 121:1996, please see the below excel table:
CIE 121:1996 Clause and Subject | LISUN MODEL |
Clause 2.2.1 Luminaire data per 1 000 lm (of lamp flux) | LPCE-2(LMS-9000) |
Clause 2.2.4-2.2.7 Light output ratio (of a luminaire) | |
Clause 6.3 Luminous flux measurements on luminaires | |
Clause 2.2.2 Luminous intensity distribution (of a luminaire) | LSG-6000 |
Clause 2.4.1-2.4.3 Photometer | |
Clause 3 CO-ORDINATE SYSTEMS FOR THE PHOTOMETRY OF LUMINAIRES | |
Clause 6.1.3 Photometric measurements on luminaires | |
Clause 6.2 Luminous intensity distribution measurements | |
Clause 2.2.3 Ballast lumen factor | HCS-109A |
Clause 2.3.6 Reference ballast | |
Clasue 7.4 Ballast lumen factor | |
Clause 2.4.4 Illuminance meter | LMS-6000 And PHOTO-200 |
Clause 6.6 Illuminance measurements | |
Clause 6.3 Luminous flux measurements on luminaires | LMS-6000L And PHOTO-200L |
LISUN supplies the fully test solutions for the following IEC 60598-2-10:2003, please see the below excel table:
IEC 60598-2-10: 2003 Clause and Subject | LISUN MODEL |
Clause 10.7 Creepage distances and clearances | CK-1 |
Clause 10.12 Endurance tests and thermal tests | GDJS-015B |
Clause 10.13 Resistance to dust, solid objects and moisture | SC-015 |
JL-X | |
Clause 10.14 Insulation resistance and electric strength | WB2681A |
Clause 10.15 Resistance to heat, fire and tracking | ZRS-3H |
ZY-3 | |
TTC-1 |
Part 5 IEC 62031: 2008 LED modules for general lighting-Safety specifications
LISUN supplies the fully test solutions for the following IEC 62031:2008, please see the below excel table:
IEC 62031:2008 Clause and Subject | LISUN Model |
3.11 heat transfer temperature for LED module | TRS-1000 |
3.12 heat output to luminaire | |
Annex D Information for luminaire design (Figure D.1) | |
3.13 ultraviolet hazard efficacy of luminours radiation | LMS-6000UV |
9. Provisons for protective earthing | WB2678A |
11.Insuation Resistance test | WB2681A |
12. Electric strength | WB2671B |
16. Creepage distance and clearances | CK-1 |
18. Resistance to heat,fire | ZRS-3H |
18. Resistance to tracking | TTC-1 |
19. Resistance to corrosion | YWX/Q-010 |
22 Photobiological safety | EN 62471-C |