Product No: YWX/Q-010X
YWX/Q-150X series Composite Salt Spray Test Machine do measurement through simulating conditions that are more commonly encountered in the natural environment such as salt spray, hot air drying, humidity, low temperature combined and loop in any order. It is widely used to test items used in drastically changing environments, such as automobile parts, aviation equipment, building materials, coating, electric and electrical machinery so on.
Standard:
GB/T2423.18 “Environmental testing – Part 2: Test methods – Test Kb: Salt mist, cyclic (sodium chloride solution)”
IEC 60068-2-52 “Enrironmental testing -Part 2-52: Tests – Test Kb: Salt mist, cyclic (sodium chloride solution)”
ISO 3769 “Metallic coatings – Acetic acid salt spray test (ASS test)”
VDA233-102 “Cyclic corrosion testing of materials & components in automotive construction”
GMW 14872 “Cyclic Corrosion Laboratory Test”
TCSAE 71 “Cyclic corrosion test methods of automotive assemblies and materials”
VCS 1027_1449 “Accelerated Cyclic Corrosion Test”
PV 1210 “Corrosion Test”
Product models:
LISUN Model | YWX/Q-250X | YWX/Q-750X | YWX/Q-010X | YWX/Q-016X | YWX/Q-020X |
Working room size | 900*600*500 | 1100*750*500 | 1200*800*500 | 1600*1000*600 | 2000*1000*600 |
External dimensions | 2160*1100*1300 | 2360*1250*1300 | 2460*1300*1350 | 2860*1500*1450 | 3260*1500*1450 |
Capacity | 270L | 412L | 480L | 960L | 1200L |
Solution tank volume | 25L | 30L | 30L | 35L | 40L |
Pure water tank volume | 30L | 35L | 35L | 40L | 50L |
Working power | Three Phase AC 380V/50HZ(60Hz can customized) | ||||
10.0KW | 12.0KW | 12.5KW | 16.0KW | 18.5KW | |
Sample space available | 700*450*250 | 900*600*300 | 1000*600*300 | 1400*800*350 | 1800*800*350 |
Opening Method | Manually control | Stainless steel air spring support | Cylinder support | ||
Working environmental temperature requirements | The ambient temperature is 5℃~30℃. Ventilation is recommended. When the temperature exceeds 30℃, it is recommended to adjust the room temperature through appropriate methods. | ||||
Working environment humidity requirements | Environmental humidity below 85%Rh | ||||
The temperature range of the salt spray chamber | 15℃~65℃ | ||||
The temperature range of saturated barrel | RT (room temperature) ~ 70 ℃ | ||||
Relative humidity of the salt spray chamber | 30%-98%RH (± 3%, adjustable, refer to the temperature and humidity corresponding chart) | ||||
Temperature performance | Temperature uniformity: ≤2 ℃ Temperature volatility: ≤ ± 1 ℃ | ||||
Salt spray deposition rate | 1-2ml/80cm²/h | ||||
Test Method | Programmable spray, moist heat, dry, standard climate | ||||
Test conditions | A. Saline spray test: NSS * test: 35 ℃ ± 2 ℃ * Saturated air barrel: 47 ℃ ± 2 ℃ | ||||
B. humidity and heat test: 1. Test temperature range: 20 ℃ -60 ℃. 2. Test humidity range: 60%RH ~ 98%RH can be adjusted. | |||||
C. Dry test: 1. Test temperature range: 20 ℃ ~ 60 ℃. 2. Test humidity range: 30%RH ~ 60%RH can be adjusted. | |||||
Standard accessories | 1 set of V -type/O -type storage racks, 1 glass nozzle, 2 bottles of sodium sodium (500g/bottle), 1 plastic rust barrel (5L ) |
Test Principle:
Composite Salt Spray Test Machine is composed of the cyclic corrosion test of the spray process, the damp and heat process, and the standing and drying process. The following are the schematic diagrams of these three processes:
1. Spray process
The system consists of salt water tank, pneumatic system, salt water storage tank, spray tower, nozzle, etc. The salt solution flows from the outside to the test chamber by using the natural drop, and the salt solution is atomized by compressed air through the spray nozzle.
2. Damp heat test
The damp heat test system is composed of steam generator, blast, water circuit, condensation device, etc. After the salt spray test, the machine will set up a defogging program to discharge the salt spray out of the test room as soon as possible; Then the water evaporator will output the appropriate temperature and humidity according to the temperature and humidity set by the controller. Generally speaking, the humidity will be more accurately calibrated and constant after the temperature is stable. The temperature and humidity parameters of the damp heat test are as follows: Temperature: 30℃—60℃; humidity: 80%RH—98%RH.
3. Drying process
Standing and drying system adds drying blower, heating wire, air filter and other devices on the basis of damp heat system, if need to simulate standard atmospheric pressure environment test (temperature 23℃±2℃, humidity 45%~55% RH). Firstly, quickly remove the damp and heat test environment in the previous section by setting a defogging program to create a relatively clean test environment, and then the humidifier or dehumidification system works in coordination under the controller to produce an environment that meets the test requirements. The temperature and humidity parameters of the drying test are as follows: temperature: 20℃-60℃; humidity: 30%~60%RH (corresponding to the appropriate temperature point).
Appendix: Temperature And Humidity Corresponding Chart: