19 Jun, 2023 798 Views Author: Raza Rabbani

The Impact of Light Source and Illumination Conditions on Portable Colorimeters Measurements

Portable colorimeters are used extensively throughout a variety of sectors, such as manufacturing, the food and beverage industry, and environmental monitoring, amongst others, to determine the color of a broad range of things or components. Yet, the light source and illumination conditions that are used during the process of color measurement might have an impact on the accuracy of the color measurements.
In this article, we will examine the factors that influence the measurements made by portable colorimeters, namely the light source and the lighting circumstances, as well as the steps that may be taken to guarantee correct color measurements.

Effect of Light Source on Color Measurements
When taking readings of color, the kind of light source that is used to do so might have a sizeable bearing on the precision of the findings. The light source has to be reliable and constant, and it should have a spectral distribution that is understood and can be predicted.

The vast majority of portable colorimeters get their light from LED bulbs, which are well-known for being reliable and consistent. Nonetheless, the spectral distribution of LEDs may change based not just on the manufacturer but also on the specific model that is being utilized.

It is vital to calibrate the portable colorimeter with a known standard sample with a known color value in order to assure accurate color readings. Calibration may be accomplished by comparing the measured value of the portable colorimeter to the value of the standard sample. As part of this procedure, the device’s parameters are altered so that they correspond to the color value of the standard sample.

This helps to ensure that the device is measuring the color of the item being measured as precisely as possible. Regular calibration is necessary, especially if the light source or any of the other measuring circumstances change. Calibration should be carried out.

 

Effect of Illumination Conditions on Color Measurements
There is a possibility that the lighting conditions that are present at the time when color measurements are being conducted will have an effect on the accuracy of the results. The words “illumination circumstances” and “lighting conditions” refer to the illumination circumstances that exist in the environment in which the object being measured is seen. Because of the fact that the lighting conditions might cause the color of an object to appear differently, it is likely that the accuracy of the color measurement will be impacted.

In order to acquire accurate readings of color, it is essential to keep the amount of light at the same level during the whole process of measurement. This is a prerequisite for success. This necessitates the creation of a viewing room or light booth that is equipped with consistent lighting settings. This is done so that all of the measurements may be carried out under the same lighting conditions. The act of standardizing illumination settings allows for a decrease in the effect that the lighting conditions have on color measurements to be achieved.

In addition to maintaining a consistent lighting environment, it is essential to take into mind the surface roughness of the object as well as the gloss of the surface. The surface’s roughness and gloss, which in turn influence the way light reflects off of the object being measured, may have an effect on the color measurement results.

In order to find a solution to this issue, it will be important to choose the measuring geometry that is the most appropriate for the thing that is being measured. As a component of the measurement geometry, the angle at which the measuring instrument is positioned in respect to the object that is being measured as well as the location at which it is positioned are both taken into consideration.
When measuring many different types of things, distinct measurement geometries are used for each sort of object. These measurement geometries are based on the surface texture and gloss of the thing that is being measured.

Conclusion
Portable colorimeters, which are used widely in a range of industries, allow for the precise measurement of the color of a wide variety of items or materials. These colorimeters come in a variety of shapes and sizes.
The accuracy of the color measurements that are collected may, however, be affected by the kind of light source and the lighting conditions that are used throughout the operation to take the measurements. To get accurate readings of color, it is essential to standardize the lighting conditions, choose appropriate measurement geometry, and calibrate the equipment on a regular basis.
If specific recommendations for how the devices should be used are adhered to, portable colorimeters have the potential to provide color measurement results that are accurate and reliable. Because of this, businesses can keep a continuous quality control, which in turn guarantees that their consumers are happy.

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are GoniophotometerIntegrating SphereSpectroradiometerSurge GeneratorESD Simulator GunsEMI ReceiverEMC Test EquipmentElectrical Safety TesterEnvironmental ChamberTemperature ChamberClimate ChamberThermal ChamberSalt Spray TestDust Test ChamberWaterproof TestRoHS Test (EDXRF)Glow Wire Test and Needle Flame Test.

Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp:+8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp:+8618117273997

Tags:

Leave a Message

Your email address will not be published. Required fields are marked *

=