+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
How dust test performed
26 Feb, 2022 2067 Author: root

How dust test performed

In addition to producing a negative influence on the sensitive electronics that underlie the guidance and communications systems of today’s military vehicles, sand and dust may also have a negative impact on the tough exterior that serves to shield those components from harm. This test is performed in a dust test chamber or dust tester. Sand and dust testing have become an essential element ...

Read More
The principle and basic calculation of CRI
24 Feb, 2022 3090 Author: Cherry Shen

The principle and basic calculation of CRI

It is well known that color table and color rendering are two important quantities that reflect the color of light sources. Light sources with different spectral power distributions can have the same color table, but the color rendering properties of several light sources with the same color table may be completely different. Therefore, only the combination of color table and color rendering can f...

Read More
Blue light hazard standard to be enforced in student classrooms
22 Feb, 2022 1392 Author: Cherry Shen

Blue light hazard standard to be enforced in student classrooms

1. What are the prevention and control plans and standards for juvenile myopia? 1.1 Adolescent myopia prevention and control program: With the increasing rate of myopia among teenagers, more and more students are becoming shortsighted. In order to protect the children’s eyes and let them have a bright future. Eight ministries and commissions including the Ministry of Education and the Nation...

Read More
How to do the RoHS Test
19 Feb, 2022 1301 Author: root

How to do the RoHS Test

Let us first attempt to comprehend what the RoHS test is and why it is seen to be significant in the first place. RoHS is an abbreviation that stands for Restriction of Hazardous Substances at its core. The Directive 2002/95/EC is sometimes referred to as the 2002/95/EC. Because it is a descendant of the European Union, it is structured only to restrict the application of some hazardous substances...

Read More
EMI receiver system for solving conducted emissions problem
17 Feb, 2022 1389 Author: Cherry Shen

EMI receiver system for solving conducted emissions problem

1. What is a conducted disturbance test? 1.1 Introduction of conducted interference: Electromagnetic interference (EMI)-The interference signals generated by electronic devices are transmitted through wires or public power lines, and mutual interference is called conducted interference. Conducted interference has brought confusion to many electronic engineers. How to solve the conducted interferen...

Read More
Comparison of vertical goniophotometer and horizontal goniophotometer
15 Feb, 2022 1367 Author: Cherry Shen

Comparison of vertical goniophotometer and horizontal goniophotometer

The goniophotometer is mainly used to measure the light distribution performance of lamps and light sources. That is, the luminosity and chromaticity value distribution of the laser source of lamps in different directions in space. 1. What are the main types of goniophotometers and what are the test methods? 1.1 Types of goniophotometer Goniophotometers are mainly divided into two types: horizonta...

Read More
How does a salt fog chamber work
12 Feb, 2022 1627 Author: root

How does a salt fog chamber work

Metal components, zinc plated nuts and bolts, surface coatings, and paint may be tested for corrosion resistance in salt spray test chambers or salt fog chambers. It is possible to test the suitability of a layer for use as a protective finish on finished items in such chambers, where coated samples are placed in a simulated corrosion environment. Corrosion-resistant samples are tested for a certa...

Read More
Integrating spheres for measuring the radiant or luminous flux of light sources
08 Feb, 2022 1500 Author: root

Integrating spheres for measuring the radiant or luminous flux of light sources

The standard specifies that the size of the integrating sphere is based on the size of the lamp under test. But experts explain that for many product development and testing purposes, smaller spheres can provide acceptable measurement accuracy. 1. What is the function of integrating sphere and what is integrating sphere? 1.1 Integrating sphere instruction: The integrating sphere is a quick and con...

Read More
How does a humidity chamber work
05 Feb, 2022 1796 Author: Cherry Shen

How does a humidity chamber work

It is possible to test the reaction of goods when they are exposed to fluctuations in humidity by using a humidity chamber. This chamber is also called an environmental chamber. Manufacturers utilize this form of environmental testing to put their goods through their paces under the most extreme circumstances possible before releasing them. Humidity chambers are used to evaluate the impact of vari...

Read More