+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
Assessing Glow-Wire Flammability Index Using Glow-Wire Tester
08 Feb, 2024 240 Author: Cherry Shen

Assessing Glow-Wire Flammability Index Using Glow-Wire Tester

The glow-wire tester is used to simulate the ignition of insulation materials or other combustible components inside equipment that may catch fire due to a hot wire or hot element. Under certain conditions, such as fault currents flowing through wires, component overloads, and poor contacts, certain components can reach a certain temperature that causes nearby parts to ignite. This can be tested t...

Read More
IEC 61032 Test Sphere Φ50 mm with Dynamometer 50N
07 Feb, 2024 236 Author: Cherry Shen

IEC 61032 Test Sphere Φ50 mm with Dynamometer 50N

1 General 1.1 Scope and object This International Standard(IEC61032) specifies details and dimensions of test probes intended to verify the protection provided by enclosures with regard to: – protection of persons against access to hazardous parts inside the enclosure; – protection of the equipment inside the enclosure against ingress of solid foreign objects. SMT IP10T_AL The object o...

Read More
How to Interpret and Analyze Waveforms on a Digital Oscilloscope
06 Feb, 2024 293 Author: Cherry Shen

How to Interpret and Analyze Waveforms on a Digital Oscilloscope

Introduction Digital oscilloscopes make it much easier for engineers to gather and display electrical waveforms for analysis, which is a common task for the profession. It is crucial to correctly interpret and analyze waveforms to get a knowledge of the behavior of circuits, which is necessary for solving issues and improving efficiency. This article will take you step-by-step through the process...

Read More
Understanding the Working Principle of a Type C Goniophotometer
05 Feb, 2024 250 Author: Cherry Shen

Understanding the Working Principle of a Type C Goniophotometer

LED, as a new type of lighting source, has many advantages such as high efficiency, energy-saving, and long lifespan, gradually replacing traditional lighting sources. However, how can we ensure the light quality and efficiency of LED lights when purchasing them? This requires LED distribution testing and glare rating testing. This article will explore the application of LM-79 Type C Goniophotomet...

Read More
IP6X Dust Test Chamber: Evaluating Dustproof Performance
04 Feb, 2024 231 Author: Cherry Shen

IP6X Dust Test Chamber: Evaluating Dustproof Performance

Dustproof test chamber is also known as IPX6 dustproof test chamber. With the rapid development of modern technology, electronic products are being widely used in our daily lives. However, due to the delicate circuits and components inside electronic products, they have low tolerance for dust and particles. Therefore, we need to conduct dustproof tests on them during production and use to ensure t...

Read More
Three-Pin Test Plug for Checking Three-Pin Flat-Pin 250 V Max. Socket-Outlets Against The Standard Test Finger with AS/NZS 3112 Figure C1
03 Feb, 2024 216 Author: Cherry Shen

Three-Pin Test Plug for Checking Three-Pin Flat-Pin 250 V Max. Socket-Outlets Against The Standard Test Finger with AS/NZS 3112 Figure C1

PREVENTION OF CONTACT WITH LIVE PINS NOTE: Fully recessed socket-outlets that comply with Clause 3.6.4 are deemed to comply with Clauses 3.8.1 and 3.8.2. During normal insertion At any stage during normal insertion of a non-insulated pin plug into a socket-outlet, with the faces of the plug and socket-outlet in parallel planes, it shall not be possible to touch, with the standard test finger (see ...

Read More
EMI Testing Equipment: The Essential EMI Test Machine and EMI Compliance Test Receiver
02 Feb, 2024 230 Author: Cherry Shen

EMI Testing Equipment: The Essential EMI Test Machine and EMI Compliance Test Receiver

With the development of technology, LED lighting fixtures have significant advantages in energy efficiency, lifespan, and color temperature. However, at the same time, LED fixtures also have some issues, one of which is EMI. In order to ensure that the EMI of LED fixtures meets the standard requirements, a dedicated instrument called LED fixture EMI Test Machine and EMI Compliance Test Receiver ha...

Read More
How to solve common faults of constant temperature humidity chamber
01 Jan, 2024 264 Author: Cherry Shen

How to solve common faults of constant temperature humidity chamber

The constant temperature humidity chamber will cause different levels of damage to the machine and equipment after long-term temperature running-in. Therefore, the following points are common troubleshooting solutions for the constant temperature humidity chamber. 1. When the constant temperature humidity chamber is conducting the high temperature test, if the temperature change cannot reach the p...

Read More
Gauge for Two-Pin Flat-Pin 125 V Max. Plugs (With Parallel Pins) of AS/NZS 3112 Figure B1
31 Jan, 2024 232 Author: Cherry Shen

Gauge for Two-Pin Flat-Pin 125 V Max. Plugs (With Parallel Pins) of AS/NZS 3112 Figure B1

TESTS General Plug portions of equipment shall be subjected to the following tests and unless stated otherwise, shall comply with the requirements specified in Section 2 for each test. The number of test samples shall be in accordance with Table 2.2. Conformance for detachable plug portions shall be established by assessment with the plug portion fully assembled with the equipment. High voltage te...

Read More