+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
Analysis of flicker parameters of several common lighting products
27 Nov, 2020 2416 Author: Cherry Shen

Analysis of flicker parameters of several common lighting products

1. Introduction of flicker parameter Flicker (light source flicker) means that the light output of the lighting source fluctuates with a certain frequency. At present, the international research results on strobe include IEEE std1789, IEC TR61547, CIE TN 006, etc. 1.1. Flicker percentage and flicker index in IEEE std1789 The flicker index refers to the area above the average light output line in a...

Read More
UV-263LS UV Aging Testing Chamber is Designed According to ISO 4892-1:2016-1 Scope
26 Nov, 2020 1917 Author: Cherry Shen

UV-263LS UV Aging Testing Chamber is Designed According to ISO 4892-1:2016-1 Scope

The full name of ISO 4892-1:2016 is Plastics-Methods of exposure to laboratory light sources-Part 1: General guidance. It was prepared by Technical Committee ISO/TC 61, Plastics, Subcommittee SC 6, Aging, chemical and environmental resistance. We will introduce the ISO 4892-1:2016-1 Scope. The following is the original content of ISO 4892-1:2016-1 Scope. This part of ISO 4892 provides information ...

Read More
Definition and Test Method of LED Flicker
26 Nov, 2020 2235 Author: Cherry Shen

Definition and Test Method of LED Flicker

LED flicker, that is, the LED liquid crystal display screen flickers. The LED liquid crystal display has a backlight strobe in low-brightness mode, similar to the old CRT display. Use your fingers to quickly shake in front of the screen to see smear. 1. LED flicker refers to two concepts: The first is flicker: the depth of fluctuating light flux of the electric light source. The greater the fluctu...

Read More
Brief talking about LM-79 Moving Detector Goniophotometer
20 Nov, 2020 1791 Author: Cherry Shen

Brief talking about LM-79 Moving Detector Goniophotometer

The LM-79 is the North American Lighting Association’s standard for test methods for LED products. The LM-79 is an electrical and photometric method for solid state lighting products. Test methods for all LED products, including test content: electrical parameters, color parameters, luminous flux, luminous efficiency, light intensity distribution, chroma non-uniformity. ENERGY STAR has a lar...

Read More
EMI conducted interference test(9KHz~30MHz) and radiation interference test(30MHz~300MHz) introduce
20 Nov, 2020 2107 Author: Cherry Shen

EMI conducted interference test(9KHz~30MHz) and radiation interference test(30MHz~300MHz) introduce

Electromagnetic interference (abbreviated as EMI) refers to the interference phenomenon caused by the interaction of electromagnetic waves and electronic components. There are two types of conducted interference and radiated interference. Conducted interference refers to the coupling (interference) of signals on one electrical network to another electrical network through a conductive medium. Radi...

Read More
EU announces new ErP regulations and energy efficiency labeling regulations for lighting products
19 Nov, 2020 2935 Author: Cherry Shen

EU announces new ErP regulations and energy efficiency labeling regulations for lighting products

On 5th, December, 2019, the European Commission officially announced the new ErP Regulation (EU) 2019/2020 and Energy Efficiency Labelling Regulation (EU) 2019/2015 for lighting products, which will replace the current ErP Regulation (EC) No 244/2009, (EC) ) No 245/2009, (EU) No 1194/2012 and Energy Efficiency Labeling Regulation (EU) No 874/2012. The new regulations have been issued for more tha...

Read More
Test Method of Tracking Test Chamber
03 Nov, 2020 2076 Author: Cherry Shen

Test Method of Tracking Test Chamber

Introduction: The TTC-1 Tracking Test Chamber which used for determining the degree of protection against formation of conducting paths in solid insulating materials, due to the electric stress and electrolytic contamination of the surface. This method simulates tracking currents on insulation material by providing drops between electrodes. During the process of normal use, insulating material may...

Read More
Junction temperature measurement for LED filament lamps
28 Oct, 2020 2213 Author: Cherry Shen

Junction temperature measurement for LED filament lamps

Abstract The improvement and spreading of the LED filaments lamps requires reliable and accurate methods and instruments for junction temperature measurement. Based on the forward voltage methods, the measurement process and the equipment of LED filaments lamps are introduced. And the dependence of junction temperature on various factors are discussed. General Though the LED filament lamp technolo...

Read More
IPX9 High Temperature Pressure Jet Waterproof Test Chamber full meet update GB/T 4208-2017 standard
27 Oct, 2020 2201 Author: Cherry Shen

IPX9 High Temperature Pressure Jet Waterproof Test Chamber full meet update GB/T 4208-2017 standard

Recently, the General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China and the National Standardization Administration approved and issued the version GB/T 4208-2017 “Enclosure Protection Level (IP Code)”. This version will replace the old GB/T 4208-2008 version and it has been officially implemented on February 1, 2018.        We...

Read More