Line and neutral socket contacts shall withstand the stresses imposed upon them by the use of socket-outlet adaptors and the like. Conformity shall be checked by the following test. The socket-outlet shall be mounted with the engagement surface of the socket-outlet in the vertical plane and with the major axis of the line and neutral pins horizontal ensuring that the shutter mechanism does not hav...
1 General 1.1 Scope and object This International Standard(IEC61032) specifies details and dimensions of test probes intended to verify the protection provided by enclosures with regard to: – protection of persons against access to hazardous parts inside the enclosure; – protection of the equipment inside the enclosure against ingress of solid foreign objects. SMT 1217_AL 1.2 The object of thi...
10. Accessibility of live parts 10.1 Live parts of plugs shall not be accessible when the plugs are wired as in normal use and in full engagement in a corresponding socket-outlet. Removal of detachable fuse carriers shall not result in live parts becoming accessible when the plug is in full engagement with the socket-outlet or the socket-outlet portion of an adaptor. 10.1.1 Conformity shall be che...
1 General 1.1 Scope and object This International Standard(IEC61032) specifies details and dimensions of test probes intended to verify the protection provided by enclosures with regard to: – protection of persons against access to hazardous parts inside the enclosure; – protection of the equipment inside the enclosure against ingress of solid foreign objects. SMT 1214_AL 1.2 The object of thi...
A set of three sample pins shall be tested by means of the apparatus shown in Figure 10 which has a blade 0.70+005mm wide and a radius of 3 mm ±0.1 mm. The test shall be made on one pin of each plug not used for the test described in 13.17.3. A sample shall be positioned as shown in Eigure 10 and the test apparatus shall be loaded so that the blade exerts a force of 2.5N on the sample. The test a...
1. General 1.1 Scope and object This International Standard specifies details and dimensions of test probes intended to verify the protection provided by enclosures with regard to: – protection of persons against access to hazardous parts inside the enclosure; – protection of the equipment inside the enclosure against ingress of solid foreign objects. The object of this International S...
1 General 1.1 Scope 1.1.1 Equipment covered by this standard This standard is applicable to mains-powered or battery-powered information technology equipment, including electrical business equipment and associated equipment, with a RATED VOLTAGE not exceeding 600 V and designed to be installed in accordance with the Canadian Electrical Code.Part1.CSA C22.1 12:General Requirements-Canadian Electric...
6 General conditions for type testing 6.1 All tests shall be type tests. Unless otherwise specified in this part of BS 1363 the socket-outlets shall be tested as delivered by the manufacturer or responsible vendor and under normal conditions of use, at an ambient temperature of 20 ℃ ±5 °C, after being conditioned at normal laboratory temperature and humidity levels for at least 4 days. GNGPL 3...
Assembly Security Test A flush receptacle having a 5-15R,5-20R,6-15R, or 6-20R configuration is to be mounted in the fixture described in Figure 124.1, and 50 lbf (220 N) is to be applied, as shown in Figure 124.2, for a period of 10 s by means of a push-out tool inserted into the slots of the receptacle. The push-out tool required for configuration 5-15R is to be as shown in Figure 124.3. The too...