+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
Why should you choose a constant current power supply for the LED driver?
06 Jan, 2019 4170 Author: root

Why should you choose a constant current power supply for the LED driver?

The LED is a light-emitting diode, and its characteristic curve is basically the same as that of a normal diode. When the applied voltage reaches the diode conduction voltage, the slight change of the applied voltage can cause a great change in the diode current. The constant current is used to ensure that the current in the LED is constant. No matter how the voltage changes, the current flowing...

Read More
Characteristics of LISUN GDJS series High and Low Temperature Humidity Chamber
05 Jan, 2019 3766 Author: root

Characteristics of LISUN GDJS series High and Low Temperature Humidity Chamber

LISUN GDJS seriesHigh and Low Constant temperature and humidity chamber  is according to IEC60068-2-1 (GB/T2423.1) and IEC60068-2-2 (GB/T2423.2). It is used to test the CFL/LED which meets IES LM-80-08, electricity products, electronic components, material and so on. There is some other manufacturers in China also produce High and Low Temperature Humidity Chamber, and LISUN VS espec temperature ...

Read More
The Status of Waterproof Test Equipment in China Market
26 Dec, 2018 4708 Author: root

The Status of Waterproof Test Equipment in China Market

Waterproof  testing grade reflects the ability of moisture-proof of products. Especially for outdoor activities, it is unavoidable to be in the harsh environment of high humidity. The sealing and water-proof ability of the instrument is very important to ensure the safe of operation and life of the instrument.     At present, there are many manufacturers producing waterproofing test equipment ...

Read More
The difference between integrating sphere test system and goniophotometer system
26 Nov, 2018 4442 Author: root

The difference between integrating sphere test system and goniophotometer system

In optical testing, the measurement of luminous flux and color temperature are essential. There are two test equipment for the measurement: Integrating Sphere Testing System and Goniophotometer. Here we give you a brief introduction to the difference of goniophotometer vs integrating sphere: 1. Integrating Sphere & Spectroradiometer Test System The Integrating Sphere Test System make me...

Read More
How to measure electric, photometric and colorimetric parameters for LED lamps and lanterns?
26 Nov, 2018 3909 Author: root

How to measure electric, photometric and colorimetric parameters for LED lamps and lanterns?

The main parameters of LED lamps and lanterns include: A: Electric parameters: voltage, current, lamp power, power factor, harmonic, etc B: Colorimetric parameters: correlated color temperature, color rendering index, chromaticity tolerance, color coordinates, SDCM, etc C: Photometric parameters: luminous flux, output luminous efficiency, beam angle, UGR table, intensity distribution, candela tab...

Read More
Brief introduction of CE certificates
20 Nov, 2018 4444 Author: root

Brief introduction of CE certificates

In recent years, the CE marks are more and more widely used in the market of European economic area (Member states of the European Union and the European Free Trade association, except Switzerland). More customs of different countries set out the requirements of CE certification for imported products. Exporter will be in trouble as well as unnecessary loss if their shipping goods don’t have CE c...

Read More
LED packaging principle
20 Nov, 2018 3447 Author: root

LED packaging principle

LED package is mainly to provide a platform for LED chips, so that LED chips have better performance of light, electricity and heat. Good packaging can make LEDs have better luminous efficiency and good heat dissipation environment, and good heat dissipation environment can enhance LEDs. The service life. LED packaging technology is mainly built on five main considerations, namely optical extracti...

Read More
How to Measure the High Frequency Fluorescent Lamp
23 Oct, 2018 4367 Author: Cherry Shen

How to Measure the High Frequency Fluorescent Lamp

High frequency fluorescent lamp came out in 1990. Fine tube, small current and high power is the distinct features. Because of the above design structure, high frequency current working, electronic ballast with low power consumption, the work system of this high frequency fluorescent lamp is superior to the traditional lamp on the aspect of lighting effect and photometric. How to measure the chara...

Read More
How to Use TM-21 and LM-80 to Estimate LED Luminaries Life?
20 Aug, 2018 6732 Author: root

How to Use TM-21 and LM-80 to Estimate LED Luminaries Life?

LED has the features of long time. According to different power drivers and use conditions, the life of LED can be up to 50,000 hours or more. LED will not extinguish directly like other light source but decay gradually. Therefore, luminous decay will lead to output low light after long time use, which will make products not meet requirements. And how to use TM-21 to estimate LED luminaries life? ...

Read More