+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語
27 Jul, 2020 2415 Views Author: Cherry Shen

Working Principle for the High and Low temperature humidity Chamber

Introduction for the High and Low temperature humidity Chamber:
High and Low temperature humidity Chamber adopts imported special man-machine interface temperature and humidity controller, which is reliable in performance, easy to operate, and the control technology has reached the current international advanced level. The cost performance is significantly better than that of similar imported equipment. Ideal equipment for alternating damp heat test. The equipment tests various materials for heat resistance, cold resistance, dry resistance and humidity resistance. It is widely use in factories of electronics, electrical appliances, food, vehicles, metals, chemicals, building materials, etc.

Working Principle for the High and Low temperature humidity Chamber

Application Area:
This equipment is mainly lead in LED industry. It conducts high temperature, low temperature and humidity tests on street lamps, fluorescent lamps, LED displays and other products. It simulates whether the products and materials have malfunctions, changes in quality, and cannot work normally after alternating temperature and humidity. It can meet different high and low temperature requirements.

The structure of the High and Low temperature humidity Chamber:

Working Principle for the High and Low temperature humidity Chamber

Standard:
Fully meet IEC60068-2-1 (GB/T2423.1) and IEC60068-2-2 (GB/T2423.2),IES LM-80-08 Standard.

Working Principle:
The working principle of refrigeration: the refrigeration cycle adopts the reverse Karro cycle, which consists of two isothermal processes and two adiabatic processes. The process is as follows: the refrigerant is adiabaticly compressed by the compressor to a higher pressure, and the consumed work causes exhaust the temperature rises, and then the refrigerant exchanges heat with the surrounding medium isothermally through the condenser to transfer heat to the surrounding medium. After the refrigerant passes through the shutoff valve adiabatic expansion to perform work, at this time the refrigerant temperature decreases. Finally, the refrigerant absorbs heat isothermally from the higher temperature object through the evaporator, so that the temperature of the cooled object is reduced. This cycle repeats to achieve the purpose of cooling down. The design of the refrigeration system applies energy adjustment technology, which can not only ensure the normal operation of the refrigeration unit, but also effectively adjust the energy consumption and cooling capacity of the refrigeration system to keep the refrigeration system in the best operating state. Using balance temperature regulation (BTC), even when the refrigeration system is working continuously, the control system controls the output of the heater through the PID automatic calculation output according to the set temperature point, and finally achieves a dynamic balance. 

As a supplier in the field of environmental test equipment, LISUN has been specialized in researching and developing a GDJS High and Low temperature humidity Chamber with many years of experience in this field of environmental test chambers. Customers can purchase proper size of test chambers according to the size of the test object. LISUN also have the high temperature chamber without humidity. If you are interested in LISUN environmental chamber price, pls. contact us. LISUN has developed the following model of test chambers:

High & Low Temperature and Humidity Chamber with Programmable Function (GDJS Series)

Model (cm)

GDJS-225*

GDJS-500*

GDJS-010*

GDJS-013*

GDJS-015*

Workroom Dimensions

50x60x75

70x80x90

100x100x100

100x100x130

100x100x150

Exterior Dimensions

105*102*200

132*132*217

167*152*231

217*152*231

245*160*231

Work Power

7.0kW

13.5kW

15.0kW

16.5kW

16.5kW

Temperature Range

A: -20℃-150℃      B: -40℃-150℃     C: -60℃-150℃

Humidity Range

30%~98% R.H

Fluctuation/Evenness

±0.5℃/±2℃

Humidity Deviation

-2%~-3% R.H

Temperature Rise Speed

1.0℃~3.0℃/min

Temperature Down Speed

0.7℃~1.0℃/min

High and Low Temperature Chamber with Programmable Function (GDJW Series)

Working Room Size

GDJW-225*

GDJW-500*

GDJW-010*

GDJW-013*

GDJW-015*

Workroom Dimensions (cm)

50x60x75

70x80x90

100x100x100

100x100x130

100x100x150

Temperature Range

A: -20℃-150℃      B: -40℃-150℃     C: -60℃-150℃

Fluctuation/Evenness

±0.5℃/±2℃

Temperature Rise Speed

1.0℃~3.0℃/min

Temperature Down Speed

0.7℃~1.0℃/min

Lisun Instruments Limited was found by LISUN GROUP in 2003. LISUN quality system has been strictly certified by ISO9001:2015. As a CIE Membership, LISUN products are designed based on CIE, IEC and other international or national standards. All products passed CE certificate and authenticated by the third party lab.

Our main products are Goniophotometer, Surge Generator, EMC Test SystemsESD Simulator, EMI Test Receiver, Electrical Safety Tester, Integrating Sphere, Temperature Chamber, Salt Spray Test, Environmental Test ChamberLED Test Instruments, CFL Test Instruments, Spectroradiometer, Waterproof Test Equipment, Plug and Switch Testing, AC and DC Power Supply.

Please feel free to contact us if you need any support.
Tech Dep: Service@Lisungroup.com, Cell/WhatsApp: +8615317907381
Sales Dep: Sales@Lisungroup.com, Cell/WhatsApp: +8618917996096

Tags:

Leave a Message

Your email address will not be published. Required fields are marked *

=