Automatic lightning surge generator (or Lightning surge immunity) SG61000-5 is used to assess the power cord and connect the internal switch stood in line to connect the internal switch to provide a common basis for switching the natural world and lightning caused by the high-energy transient interference performance. Performance fully meets the IEC 61000-4-5, EN61000-4-5 and GB/T17626.5 standards.

Specifications:

Product ModelSG61000-5SASG61000-5NASG61000-5SBSG61000-5NBSG61000-5SG61000-5H-SPSG61000-5H15-SPSG61000-5TSG61000-5H
Output Voltage (Open)1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%1.2/50μs±20%
Output Current (Short)8/20μs±20%8/20μs±20%8/20μs±20%8/20μs±20%8/20μs±20%8/20μs±20%8/20μs±20%8/20μs±20%8/20μs±20%
Output Impedance2Ω and 12Ω2Ω and 12Ω2Ω and 12Ω2Ω and 12Ω2Ω and 12Ω2Ω 12Ω and 500Ω2Ω 12Ω and 500Ω2Ω and 12Ω2Ω 12Ω and 500Ω
Output Voltage Range0~4.8KV±10%0~6KV±10%0~4.8KV±10%0~6KV±10%0~6KV±10%0~10KV±10%0~15KV±10%0~6KV±10%0~10KV±10%
Output Current Range0~2.4KA±10%0~3KA±10%0~2.4KA±10%0~3KA±10%0~3KA±10%0~5KA±10%0~7.5KA±10%0~3KA±10%0~5KA±10%
Surge Repetition1~9999 times1~9999 times1~9999 times1~9999 times1~9999 times1~9999 times1~9999 times1~9999 times1~9999 times
Interval Time20~9999s20~9999s20~9999s20~9999s20~9999s30~9999s40~9999s20~9999s30~9999s
PolarityPositive, Negative or Positive/Negative automatic
Phase ShiftAsynchronous, Synchronization 0°~ 360° or Specific Angle
Special FunctionN/ABuilt-in surge voltage and current probe (1000:1), connect with LISUN JC2202TA directly
Operation WayButton InputTouch screen with super big LCD and built-in Windows CE
Dimensions (WxDxH)44x45x35cm44x45x35cm44x45x35cm56x69x155cm56x69x155cm44x45x55cm56x69x155cm
Gross WeightAbout 30kgAbout 30kgAbout 30kgAbout 270kgAbout 350kgAbout 48kgAbout 270kg
Coupling/Decoupling Network (CDN)Includes a 16A single phase CDNIncludes a 20A 3phases CDN
Isolution Transformer for EUT (Option)LISUN ITEU-SP4K (220V Single phase) or ITUS-SP2K (110V)LISUN ITEU-TP10K or ITUS-TP5K

Remark: 12KV, 20KV and more higer voltage Surge Generator can be designed according to customer request.

 

Surge Generator

6KV Short Circuit Current Output Waveform (780:1)               6KV Open Circuit Voltage Output Waveform (1000:1)

Related Technical Articles
1. LISUN engineers to India customers to carry out lightning surge generator installation training.
2. Surge Immunity Test Combination Wave Generator
3. IEC 61000-4-5:2014 Surge Immunity Test
4. Analysis for Surge Immunity
5. IEC 61000-4-5: Surge Test and Measurement Techniques
6. Costa Rica – Installation and training Integrating Sphere Test System, dustproof and waterproof test equipment, EMI/EMC test machine, etc.
7. LISUN Engineer do installation and training in Algeria
8. LISUN engineer Joye do installation and training in Korea
9. The Lighting Product EMC Problem and Testing Technology
10. Indian customer ordered full sets of EMC and EMI Equipments
11. What’s new: IEC 61000-4-5 Second Edition vs. Third Edition

 

Related Instruments