Product No: PHOTO-200
The PHOTO-200 series Lux Meter | Brightness Meter | PPFD Meter | UV Irradiance Meter use high-precision linear optoelectronic sensor, which has the characteristics of lightweight, stable performance, high accuracy, high cost performance, and easy carrying. Widely used on-site lighting measurement, the research and development of light source products, quality monitoring of production lines, and plant factories.
Specification:
Detector Accuracy | Class A (± 4%reading ± 1 reading) |
Reproducibility | ±0.5% |
Display method | Touch screen (can expand: PC, mobile APP) |
Screen Size | 1.54 “IPS HD LCD touch screen |
Screen type | 180 degrees rotation |
Communication method | USB、Bluetooth |
Charging interface | Type-C |
Power supply | 1600mA lithium battery |
Continuous work time | It can be used continuously for 12 hours after one charge |
Product Size | 65mm*60mm*60mm |
Product weight | Aluminum alloy body, 100g |
Secondary development | Support |
Order Model:
LISUN Model | Product Name | Test Parameters and Specification |
PHOTO-200 | Pocket Illuminance Meter | Illuminance lux test range (380-780nm): 0.1-500,000lx (±0.1lx), upper and lower limit settings, sorting tests, optical change curves (PC software), illuminance, average illuminance, maximum illuminance, minimum illuminance, point illumination, illuminance transmission (%) |
PHOTO-200L | Pocket Brightness Meter | Brightness test range (380-780nm): 0.1-500,000cd/m² (±0.1cd/m²), upper and lower limit settings, sorting test, light change curve (PC software), brightness, average brightness, maximum brightness, minimum brightness, points brightness, brightness transmission (%) |
PHOTO-200P | PPFD Sensor and Lux Meter | Illuminance lx, PPFD umol/m².s (400-700nm) test range: 0.1-500,000umol/m².s (±0.01umol/m².s) , Up and down limit settings, sorting tests, optical change curves (PC software), PPFD, average PPFD, maximum PPFD, minimum PPFD, energy, transmission ratio (%), testing time |
PHOTO-200DLI | PPFD Sensor(DLI) | PPFD umol/m².s (400-700nm) test range: 0.1-500,000umol/m².s (±0.01umol/m².s), total amount of effective radiation umol/m².d |
PHOTO-200B | Blue Light Irradiance (460nm) | Irradiance μW/cm² (peak: 460nm) test range: 0.1-200,000μW/cm² (±0.1μW/cm²), upper and lower limit settings, sorting tests, optical change curves (PC software), irradiation, average Irradiance degree, maximum Irradiance, minimum Irradiance degree, minimum Irradiance, degree Blu -ray energy μJ/cm², Irradiance transmission ratio (%), testing time |
PHOTO-200UV | UV Irradiance | Irradiance μW/cm²(222 nm or 254nm or 365nm) test range: 0.1-500,000μW/cm² (±0.01μW/cm²), upper and lower limit settings, sorting tests, optical change curves (PC software), Irradiance degree, average Irradiance degree, maximum Irradiance, minimum Irradiance, UV energy, radiation transmission ratio (%), testing time |
PHOTO-200UVZ | UV Irradiance (Multiband) | Irradiance μW/cm²(254nm and 365nm) test range: 0.1-500,000μW/cm² (±0.01μW/cm²), upper and lower limit settings, sorting tests, optical change curve (PC software), radiation, average radiation, maximum radiation, minimum radiation, UV energy, radical transmission ratio (%), testing time |
PHOTO-200R | Red Light Irradiance (650nm) | Irradiance μW/cm² (Peak: 650nm) test range: 0.1-200,000μW/cm² (±0.1μW/cm²), upper and lower limit settings, sorting tests, light change curve (PC software), irradiation, average radiation degree, maximum radiation, minimum radiation, red light energy μJ/cm², radiation transmission ratio (%), testing time |
PHOTO-200IR | nIR Irradiance | Irradiance μW/cm² (850 nm or 940nm) test range: 0.1-500,000μW/cm² (±0.01μW/cm²) |
PHOTO-200IRZ | nIR Irradiance (Multiband) | Irradiance μW/cm² (850 nm and 940nm) test range: 0.1-500,000μW/cm² (±0.01μW/cm²) |