+8618117273997weixin
English
中文简体 中文简体 en English ru Русский es Español pt Português tr Türkçe ar العربية de Deutsch pl Polski it Italiano fr Français ko 한국어 th ไทย vi Tiếng Việt ja 日本語

IEC 60884-1 IEC 60669-1 Clause 12.3.11 Electrical and Thermal Stresses Test Device

Product No: JCY-1

Leave a Message

=
  • Description
  • Video
  • The JCY-1 Screwless Terminals withstand the electrical and Thermal stresses Test Device fully comply with Clause 12.3.11 of IEC 60884-1:2022 (GB/T 2099.1-2021) and IEC 60669-1:2017 (GB/T 16915.1-2024). During operation, the test current is connected according to the standard. After a certain period, the voltage drop is measured (judgment criterion: the voltage drop is not greater than 22.5mV) to inspect whether the non-threaded terminals can withstand the electrical and thermal stresses that occur during normal use.

    Specification:
    • Voltage meter range: 0~50mV (3%±1A)
    • Current meter range: 0~30A (3%±1mV)
    • Supply voltage: 4~12V
    • Supply current: 0~30A
    • Test cycle setting: 0~9,999 times

    Note: The JCY-1 Screwless Terminals withstand the electrical and Thermal stresses Test Device is typically used in conjunction with the JCY-2 Screwless Terminals Bending Test Device .

    IEC 60884 1 Clause12.3.1

    Tags:
  • JCY-1 Screwless Terminal Electrical and Thermal Stresses Test and JCY-2 Screwless Terminal Deflection Test Device - Product Introduction

    vedio