This Standard UL 1598: 2012 is issued jointly by the Association of Standardization and Certification (ANCE), the Canadian Standards Association (CSA),and Underwriters Laboratories Inc. (UL). Comments or proposals for revisions on any part of the standard may be submitted to ANCE, CSA, or UL at any time. Revisions to this standard will be made only after processing according to the standards development procedures of ANCE, CSA,and UL. CSA and UL will issue revisions to this standard by means of a new edition or revised or additional pages bearing their date of issue. ANCE will incorporate the same revisions into a new edition of the standard bearing the same date of issue as the CSA and UL pages.

LISUN supplies the fully test solutions for the following UL 1598: 2012, please see the below excel table:

UL 1598: 2012 Clause and Subject LISUN Model
Clause 3 Ballast Tester WT5000
Clause 5.6 Corrosion protection YWX/Q-010
Clause 13.4.2 Corrosion protection
Clause 6.7.1.5 HID Ballast Tester WT2000-HID
Clause 6.11.1 Creepage Distances CK-1
Clause 6.12 Electrical insulation WB2681A
Clause 6.14 Grounding and bonding WB2678A
Clause 18.2 Grounding continuity
Clause 12.2.3.1 Plastic material flame ZY-3
Clause 16.3 Five-inch Flame
Clause 16.27 Needle flame
Clause 19.24&19.31 Five-inch flame test apparatus
Clause 12.3.3.1 Temperature GDJS-015B
Clause 12.3.3.2 Thermal shock HLST-500D
Clause 16.28 Lamp containment barrier thermal shock
Clause 16.2.3 Impact IK01-06
Clause 16.5.7 Impact conditioning
Clause 16.22 Tempered glass impact
Clause 16.2.5.2 Torque CH338
Clause 16.33 Lampholder mounting torque
Clause 19.27 Lampholder mounting torque test apparatus
Clause 16.5.1-16.5.4 Wet Locations JL-X
Clause 19.17 Rain test apparatus
Clause 19.18 Sprinkler test apparatus
Clause 16.5.5 UV exposure conditioning UV-263LS
Clause 19.25 UV exposure test apparatus
Clause 16.5.6 Polymeric thermal conditioning GW-500
Clause 16.5.8 Luminaire gasket assembly accelerated aging
Clause 16.5.9 Gasket accelerated aging(Method A)
Clause 16.5.10 Gasket accelerated aging (Method B)
Clause 16.6 Hot-wire ignition (HWI) RSY-LT
Clause 16.7 Glow-wire end product ZRS-3H
Clause 19.28 Glow-wire test apparatus
Clause 16.8 High-current arc ignition (HAI) HCAI-2
Clause 16.16-16.17 Snap-in or tab-mounted parts pull test with/without conduit opening LNSYJ-1
Clause 16.25 Horizontal burning flame HVR-LS
Clause 16.26 Vertical burning flame
Clause 19.29 Horizontal burning flame test apparatus
Clause 19.30 Vertical burning flame test apparatus
Clause 17.1&18.1 Dielectric voltage-withstand LS9923
Clause 19.20 Dielectric voltage-withstand test apparatus
Clause 17.2 Bonding circuit impedance LS90
Clasue 19.21 Impact test apparatus ZBP-T
Clasue 19.22 Articulate probe SMT-PA100A